KD33S Long-Tube Aromatherapy Facial Steamer

An entry-level corded warm-mist facial-steamer platform for beauty brands, importers and distributors seeking a clear home-beauty proposition with an adjustable long nozzle and aromatherapy-oriented structure.

  • Distinctive long-nozzle format separates the model from compact fixed-nozzle steamers
  • A designated aroma-pad compartment supports an aromatherapy-oriented retail story
  • Straightforward corded operation suits focused home-beauty assortments
  • Sample, bulk-supply and private-label routes can be evaluated for qualified projects
Commercial Position
Entry-Level
Buyer Profile
Brands & Importers
Channel Fit
Retail & E-Commerce
Project Route
Bulk / Private Label

Where the KD33S Fits in the Market

Three commercial roles help buyers decide whether the KD33S fits their facial-care portfolio and channel strategy.

01

Entry-Level Home-Beauty Assortments

For brands adding a straightforward corded warm-mist facial steamer to an established home-beauty range without introducing unrelated premium functions.

02

Aromatherapy-Oriented Private Label

For private-label programs built around the adjustable long nozzle and designated aroma-pad compartment rather than medical or unverified treatment claims.

03

Retail, Distribution & E-Commerce

For importers, distributors and established online sellers that need a clearly positioned facial-steamer model with branding and packaging options.

Woman using the KD33S long-tube warm-mist facial steamer White KD33S warm-mist facial steamer with adjustable long nozzle White and pink KD33S facial steamer color options

Does the KD33S fit your market?

Share your target channel and project brief so our team can review product fit and configuration options.

The Product Systems Behind the KD33S

Four model-specific systems explain how the KD33S is configured and what buyers should verify before sample approval.

KD33S water system, aroma-pad compartment and control details

PTC Warm-Mist Heating

PTC heating produces warm mist for the KD33S home facial-steaming platform. Output should be evaluated against the approved sample rather than an unconfirmed warm-up time, steam temperature or operating duration.

Confirmed function boundary: warm mist only; no confirmed cold-mist, negative-ion or ozone functions.

360-Degree Adjustable Long Nozzle

The long nozzle supports flexible positioning during sample evaluation. Buyers should review the full rotation range, joint feel and whether the nozzle remains stable at the intended angle.

Confirm rotation range and positioning stability with the approved sample.

Aroma-Pad Compartment

A separate aroma-pad compartment supports the product's aromatherapy-oriented positioning without changing the water-tank system.

Use only the designated aroma-pad compartment; do not add oils, herbs or other materials directly to the water tank unless the approved manual permits it.

Water-Tank System

The confirmed 100 ml tank supports the KD33S compact tabletop format. Buyers should inspect tank seating, filling, the visible water level, sealing and leakage during sample review.

Operating duration per full tank must be confirmed against the approved version and test conditions.

How to Evaluate a KD33S Sample

Approve the sample from observed performance and build quality—not appearance alone. Record each result against the confirmed specification and reference sample.

KD33S facial steamer with adjustable long nozzle movement

Warm-Mist Output

  • Check continuity and operating stability throughout the test
  • Compare output consistency with the approved reference sample
  • Record observations without relying on unconfirmed timing claims

Nozzle Movement & Positioning

  • Review movement across the full adjustment range
  • Check joint feel and stability at different angles
  • Confirm the nozzle holds its intended position during operation

Tank Fit, Filling & Leakage

  • Check tank seating, cap fit and the filling process
  • Review the visible water level during operation
  • Inspect seals and surrounding surfaces for leakage

Controls & Indicators

  • Confirm consistent switch response through repeated cycles
  • Check indicator behavior against the approved sample
  • Review control labeling for clarity and correct placement

Electrical & Cord Review

  • Match the sample to the approved market configuration
  • Inspect the cord, strain relief, plug and connection points
  • Confirm power markings agree with the submitted specification

Aroma Structure & Pack-Out

  • Check the designated aroma-pad compartment fit and condition
  • Review housing joints, finish and overall assembly consistency
  • Confirm manuals, labels and pack-out match the approved version

Configure the KD33S for Your Market

Define the branding, packaging and electrical version that must be approved before quotation and production.

Brand Identity

Logo application and supported product or packaging graphics can be evaluated for the KD33S commercial version.

Customized logo Evaluation
Packaging graphics and artwork Evaluation
Product color To Be Confirmed
Surface finish To Be Confirmed
Final process, artwork and minimum quantity depend on the approved project scope.

Packaging, Labels & Manuals

Commercial packaging, labels, warnings and manual language must match the destination market and approved order version.

Branded packaging Evaluation
Product and warning labels To Be Confirmed
Manual language localization To Be Confirmed
Packaging language To Be Confirmed
Confirm the final artwork, label content, manual language and pack-out before production.

Market Electrical Configuration

Plug type, voltage and frequency must be matched to the destination market and the approved product version.

Plug type To Be Confirmed
Voltage configuration To Be Confirmed
Rated frequency To Be Confirmed
Deeper OEM/ODM changes Eng. Review
Provide the destination market and estimated quantity so feasibility can be reviewed accurately.

Ready to configure your KD33S version?

Explore our Private Label and OEM & ODM service pages for broader context.

KD33S Specifications & Packaging

Confirmed core specifications are separated from packaging and market-version information to support accurate sourcing review.

ItemStandard Specification
ModelKD33S
Product NameLong-Tube Aromatherapy Facial Steamer
Main FunctionsWarm facial steaming, hydration and aromatherapy
Steam TypeWarm mist
Heating MethodPTC
Rated Power350 W
Water Tank Capacity100 ml
Product Dimensions198 × 98 × 147 mm
Net Weight726 g
Nozzle360-degree adjustable long nozzle
Aroma StructureDesignated aroma-pad compartment
ItemStandard Packing Information
Individual Packaging Dimensions195 × 135 × 157 mm
Carton Quantity20 units
Master Carton Dimensions705 × 412 × 338 mm
Current Packing ListMain unit and product manual, subject to final order confirmation
Configuration AreaNotes
Destination Market InformationRequired before quotation and version selection
Electrical ConfigurationPlug, voltage and frequency matched to the approved market version
Branding ScopeLogo, color and surface finish reviewed against the project brief
Packaging & LanguagesArtwork, labels, warnings and manual language confirmed before production
Supporting DocumentsMatched to the actual model version, rated configuration and destination market

Quality Checks, Supporting Documents & Related Models

Review the production-control flow, applicable evidence and related facial-steamer platforms. Some factory records use model K33S, which corresponds to the KD33S commercial model on this page.

Production Quality Control Flow

Incoming material and component verification
Heating, nozzle and water-system assembly control
In-process electrical and control verification
Final functional inspection against the approved sample
Label, manual and pack-out verification
Approved-sample and order-version traceability

Supporting Documents

Quality Inspection Report
WTS2024-27445; factory model K33S corresponding to commercial model KD33S.
UL 859 Test Report
HTT202311255LR; applicability must be confirmed for the actual rated version.
FCC Test Report
HTT202205474FR; applicability must be confirmed for the actual product version.
China Standards Reference
GB 4706.1-2005 and GB 4706.15-2008 technical references.
China Standards Reference
GB 4343.1-2018 and GB 17625.1-2022 technical references.
ISO 9001:2015
Company-level quality-management-system certificate; not a product certification.

Related Facial Steamer Models

ModelProduct DirectionMain DifferenceBetter Suited For
KD2331A Compact facial-steamer platformAlternative compact product architectureBuyers comparing a more compact home-beauty format
KD2332 Multifunction facial-steamer platformAlternative feature and control architecturePrograms requiring a broader facial-steamer proposition
KD2328 Large-format facial-steamer platformAlternative capacity and product formatBuyers evaluating a larger facial-steamer platform

Common Sourcing Questions

Answers for brands, importers and buyers evaluating the KD33S.

What information is required for a KD33S quotation?

Provide the destination market, estimated quantity, required plug and electrical configuration, branding scope, packaging requirements and preferred delivery schedule. This information allows the team to confirm the appropriate version and commercial scope.

Can a buyer order a sample before confirming a bulk order?

Sample availability can be discussed before bulk approval. The sample should be reviewed against the confirmed specification, and the approved sample should remain the reference for function, finish, labeling and pack-out.

Which plug, voltage and frequency versions can be evaluated?

The electrical configuration must be matched to the destination market and approved product version. Share the target country or region so the available plug, voltage and frequency combination can be confirmed accurately.

Why do some supporting documents show model K33S?

K33S is the factory-model reference used in some supporting records and corresponds to the KD33S commercial model shown on this page. Document applicability still depends on the exact rated configuration and product version.

Which KD33S elements can be customized?

Logo application, packaging artwork, labels, warnings and manual language can be evaluated. Product color, surface finish and deeper OEM/ODM changes require a separate feasibility and minimum-quantity review.

Which reports and supporting records are available?

Available references include quality inspection report WTS2024-27445, UL 859 test report HTT202311255LR, FCC test report HTT202205474FR, applicable China technical references and a company-level ISO 9001:2015 QMS certificate. Test reports are not product certifications, and every record must be matched to the actual version and destination market.

MOQ, sample availability and customization scope are confirmed per project.